This section describes how to configure proper MPLS OAM parameters on both ends of a PW for network loads.
The system view is displayed.
The MPLS view is displayed.
MPLS OAM is globally enabled.
Return to the system view.
The MPLS-OAM view is displayed.
MPLS OAM parameters are configured on the node at each end of a PW.
If OAM auto protocol extension is enabled in Step 6, Step 7 does not need to be performed. When OAM auto protocol extension is enabled, a device automatically sends or receives OAM detection packets.
After receiving the first CV or FFD packet, the egress automatically records OAM parameters, such as the detection packet type and interval at which detection packets are sent. The egress then uses these parameters to monitor link connectivity.
The same compatibility mode must be set to ensure interworking between different products.
When OAM auto protocol extension is enabled, the compatibility-mode parameter must be set to the same value on the local and peer devices.
MPLS OAM is enabled on the node at each end of the PW.
The packet loss alarm threshold of OAM packets is set.
The single-ended packet loss measurement of PW MPLS OAM is enabled.
The proactive PW two-way delay measurement is enabled.
The configuration is committed.