Single-ended Frame Loss Measurement When an L2VPN Is Connected to an L3VPN

When an L2VPN is connected to an L3VPN, single-ended frame loss measurement is enabled to monitor link quality. This helps prevent CCMs from overloading the network.

Context

Single-ended frame loss measurement measures frame loss on demand or proactively. On-demand single-ended frame loss measurement is manually initiated for diagnosis of frame loss in a limited time. It can be singular or periodic measurement. Proactive single-ended frame loss measurement is performed continuously to permit proactive reporting of frame loss or performance results.
  • The on-demand mode is manually initiated and allows frame loss statistics to be collected at a time or a specific number of times for diagnosis.

  • The proactive mode allows frame loss statistics to be collected periodically.

Procedure

  • Configure on-demand single-ended frame loss measurement.

    1. Perform the following steps on the MEP and RMEP:
      1. Run system-view

        The system view is displayed.

      2. Run cfm md md-name

        The MD view is displayed.

      3. Run ma ma-name

        The MA view is displayed.

      4. Run mep mep-id

        An outward-facing MEP is configured.

      5. Run remote-mep mep-id mep-id

        An RMEP ID is specified.

      6. Run mep ccm-send enable

        The MEP is enabled to send CCMs.

      7. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The RMEP is enabled to receive CCMs.

    2. Configure a test instance.

      1. On the receiver RMEP, run test-id test-id [ testid-file ]mep mep-id [ description description ]

        A test instance is configured.

      2. On the initiator MEP, run test-id test-id [ testid-file ]mep mep-id [ mac mac-address | remote-mepmep-id ] [ description description ]

        A test instance is configured.

    3. On the receiver RMEP, run loss-measure single-ended receivetest-idtest-id-value

      The RMEP is enabled to receive LMMs.

    4. On the initiator MEP, run loss-measure single-ended sendtest-idtest-id-valueinterval { 1000 | 10000 } countcount-value

      Single-ended frame loss measurement is configured.

    5. Run commit

      The configuration is committed.

  • Configure proactive single-ended frame loss measurement.

    1. Perform the following steps on the MEP and RMEP:
      1. Run system-view

        The system view is displayed.

      2. (Optional) Run y1731 pm-mode enable

        Proactive statistics are sent by the performance management (PM) module to an NMS.

      3. Run cfm md md-name

        The MD view is displayed.

      4. Run ma ma-name

        The MA view is displayed.

      5. Run mep mep-id

        A MEP is configured.

      6. Run remote-mep mep-id mep-id

        An RMEP ID is specified.

      7. Run mep ccm-send enable

        The MEP is enabled to send CCMs.

      8. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The RMEP is enabled to receive CCMs.

      9. (Optional) Run loss-measure single-ended local-ratio-threshold mep mep-id upper-limit upper-limit lower-limit lower-limit [ 8021p 8021p-value ]

        Upper and lower thresholds are set for the near-end frame loss rate in proactive single-ended frame loss measurement based on a specified MEP.

      10. (Optional) Run loss-measure single-ended remote-ratio-threshold mep mep-id upper-limit upper-limit lower-limit lower-limit [ 8021p 8021p-value ]

        Upper and lower thresholds are set for the far-end frame loss rate in proactive single-ended frame loss measurement based on a specified MEP.

    2. Configure a test instance.

      1. On the receiver RMEP, run test-id test-id [ testid-file ]mep mep-id [ description description ]

        A test instance is configured.

      2. On the initiator MEP, run test-id test-id [ testid-file ]mep mep-id [ mac mac-address | remote-mepmep-id ] [ description description ]

        A test instance is configured.

      3. (Optional) Run loss-measure single-ended local-ratio-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

        Upper and lower thresholds are set for the near-end frame loss rate in proactive single-ended frame loss measurement based on a specified test instance.

      4. (Optional) Run loss-measure single-ended remote-ratio-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

        Upper and lower thresholds are set for the far-end frame loss rate in proactive single-ended frame loss measurement based on a specified test instance.

    3. On the receiver RMEP, run loss-measure single-ended receive test-id test-id-value

      The RMEP is enabled to receive LMMs.

    4. On the initiator MEP, run loss-measure single-ended continual send test-id test-id-value interval interval-value [ period period ]

      Proactive single-ended frame loss measurement is configured.

    5. Run commit

      The configuration is committed.

Verifying the Configuration

After completing the configuration, run the display y1731 statistic-type single-loss [ test-id test-id-value ] [ count count-value ] command on the MEP that initiates single-ended frame loss measurement and verify the configuration.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >