Configuring Single-ended SLM in VLAN Networking

This section describes how to configure single-ended synthetic loss measurement (SLM) in virtual local area network (VLAN) networking. To collect performance statistics for frame loss on point-to-multipoint or multipoint-to-multipoint links, deploy single-ended SLM, which helps monitor link quality.

Context

In VLAN networking, single-ended SLM includes on-demand and proactive SLM functions. On-demand SLM collects single-ended frame loss statistics at one or more specific times for diagnosis. It is used on the pseudo wire (PW) or attachment circuit (AC) side. Proactive SLM collects single-ended frame loss statistics periodically. It is used on the PW side only.
  • To collect performance statistics about frame loss at a time or periodically, configure single-ended on-demand synthetic frame LM.

  • To continuously collect performance statistics about frame loss, configure single-ended proactive synthetic frame LM.

Procedure

  • Configure single-ended on-demand SLM.

    1. Perform the following steps on the devices at both ends of a link on a VLAN where single-ended on-demand SLM will be implemented:
      1. Run system-view

        The system view is displayed.

      2. Run cfm enable

        CFM is enabled globally.

      3. Run cfm md md-name

        The MD view is displayed.

      4. Run ma ma-name

        The MA view is displayed.

      5. Run map vlan vlan-id

        The maintenance association (MA) is bound to a VLAN.

      6. Run mep mep-id

        A maintenance association end point (MEP) is configured.

      7. Run remote-mep mep-id mep-id

        A remote MEP (RMEP) is specified.

      8. Run mep ccm-send enable

        The MEP is enabled to send continuity check messages (CCMs).

      9. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The RMEP is enabled to receive CCMs.

      10. Run test-id test-id [ testid-file ]mep mep-id [ description description ]

        A test instance is created.

    2. Perform the following configuration on the RMEP that receives SLM frames:

      Run loss-measure single-ended-synthetic receive test-id test-id [ time-out timeout-value ]

      The RMEP is enabled to receive SLM frames.

    3. Perform the following configuration on the MEP that sends SLM frames to initiate on-demand SLM:

      Run loss-measure single-ended-synthetic send test-id test-id interval { 100 | 1000 } [ sending-count count-value ] [ time-out time-out-value ]

      The MEP is enabled to send SLM frames.

    4. Run commit

      The configuration is committed.

  • Configure single-ended proactive SLM.

    1. Perform the following steps on the devices at both ends of a link on a VLAN where single-ended proactive SLM will be implemented:
      1. Run system-view

        The system view is displayed.

      2. (Optional) Run y1731 pm-mode enable

        Performance management (PM) is enabled to manage Y.1731 proactive performance statistics.

      3. Run cfm enable

        CFM is enabled globally.

      4. Run cfm md md-name

        The MD view is displayed.

      5. Run map vlan vlan-id

        The MA is bound to a VLAN.

      6. Run mep mep-id

        A MEP is configured.

      7. Run remote-mep mep-id mep-id

        An RMEP is specified.

      8. Run mep ccm-send enable

        The MEP is enabled to send CCMs.

      9. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The RMEP is enabled to receive CCMs.

      10. Run test-id test-id [ testid-file ]mep mep-id [ description description ]

        A test instance is created.

      11. (Optional) Run loss-measure single-ended-synthetic local-ratio-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

      12. (Optional) Run loss-measure single-ended-synthetic remote-ratio-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

    2. Perform the following configuration on the RMEP that receives SLM frames:

      Run loss-measure single-ended-synthetic receive test-id test-id [ time-out timeout-value ]

      The RMEP is enabled to receive SLM frames.

    3. Perform the following configuration on the MEP that send SLM frames to initiate proactive SLM:

      Run loss-measure single-ended-synthetic continual send test-id test-id interval { 1000 | 10000 } [ sending-count count-value ] [ time-out timeout ] [ period period ]

      The MEP is enabled to send SLM frames.

    4. Run commit

      The configuration is committed.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.