Configuring Single-ended Frame Loss Measurement in EVPN Networking

In EVPN networking scenarios where CFM is enabled, if CCMs are not used for link connectivity monitoring to minimize their impact on the network, you can configure single-ended frame loss measurement to measure frame loss rates and monitor link quality.

Context

Single-ended frame loss measurement in EVPN networking can be either on-demand or proactive. On-demand single-ended frame loss measurement is manually initiated for diagnosis of frame loss within a limited period of time. It can be performed once or multiple times (the number of times is configurable). Proactive single-ended frame loss measurement is continuously performed to allow proactive reporting of frame loss or performance results.
  • Configure on-demand measurement if you need the device to collect single-ended frame loss statistics for a specified number of times.

  • Configure proactive measurement if you need the device to collect single-ended frame loss statistics continuously.

Procedure

  • Configure on-demand single-ended frame loss measurement for an AC.

    1. Perform the following steps on the MEP and RMEP:
      1. Run system-view

        The system view is displayed.

      2. Run cfm md md-name

        The MD view is displayed.

      3. Run ma ma-name

        The MA view is displayed.

      4. Perform the following steps on the devices where the MEP and RMEP reside:

        • On the CE, run map vlan vlan-id

          The MA is bound to a VLAN.

        • On the PE, run map { evpn vpn-instance evpn-instance-name | bridge-domain bd-id }

          The MA is bound to a specified EVPN instance.

          For EVPN VPWS or EVPN VPLS in common AC interface mode, specify evpn vpn-instance evpn-instance-name.

          For EVPN VPLS in BD mode, specify bridge-domain bd-id.

      5. Run mep mep-id mep-id interface interface-type interface-number outward

        An MEP is configured.

      6. Run remote-mep mep-id mep-id

        An RMEP is configured.

      7. Run mep ccm-send enable

        The MEP is enabled to send CCMs.

      8. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The MEP is enabled to receive CCMs from the RMEP.

    2. Configure test instances.

      1. On the receiver RMEP:

        Run test-id test-id [ testid-file ] mep mep-id [ description description ]

        A test instance is configured.

      2. On the initiator MEP:

        Run test-id test-id [ testid-file ] mep mep-id [ mac mac-address | remote-mep mep-id ] [ description description ]

        A test instance is configured.

    3. On the receiver RMEP:

      Run loss-measure single-ended receive test-id test-id-value

      The RMEP is enabled to receive LMMs.

    4. On the initiator MEP:

      Run loss-measure single-ended send test-id test-id-value interval { 1000 | 10000 } count count-value

      On-demand single-ended frame loss measurement is enabled.

    5. Run commit

      The configuration is committed.

  • Configure proactive single-ended frame loss measurement for an AC.

    1. Perform the following steps on the MEP and RMEP:
      1. Run system-view

        The system view is displayed.

      2. (Optional) Run y1731 pm-mode enable

        PM is enabled to manage and send Y.1731 proactive performance statistics to the NMS.

      3. Run cfm md md-name

        The MD view is displayed.

      4. Run ma ma-name

        The MA view is displayed.

      5. Perform the following steps on the devices where the MEP and RMEP reside:

        • On the CE, run map vlan vlan-id

          The MA is bound to a VLAN.

        • On the PE, run map { evpn vpn-instance evpn-instance-name | bridge-domain bd-id }

          The MA is bound to a specified EVPN instance.

          For EVPN VPWS or EVPN VPLS in common AC interface mode, specify evpn vpn-instance evpn-instance-name.

          For EVPN VPLS in BD mode, specify bridge-domain bd-id.

      6. Run mep mep-id mep-id interface interface-type interface-number outward

        An MEP is configured.

      7. Run remote-mep mep-id mep-id

        An RMEP is configured.

      8. Run mep ccm-send enable

        The MEP is enabled to send CCMs.

      9. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The MEP is enabled to receive CCMs from the RMEP.

      10. (Optional) Run loss-measure single-ended local-ratio-threshold mep mep-id upper-limit upper-limit lower-limit lower-limit [ 8021p 8021p-value ]

        Lower and upper thresholds are set for the near-end frame loss rate in proactive single-ended frame loss measurement on a specified MEP.

      11. (Optional) Run loss-measure single-ended remote-ratio-threshold mep mep-id upper-limit upper-limit lower-limit lower-limit [ 8021p 8021p-value ]

        Lower and upper thresholds are set for the far-end frame loss rate in proactive single-ended frame loss measurement on a specified MEP.

    2. Configure test instances.

      1. On the receiver RMEP:

        Run test-id test-id [ testid-file ] mep mep-id [ description description ]

        A test instance is configured.

      2. On the initiator MEP:

        Run test-id test-id [ testid-file ] mep mep-id [ mac mac-address | remote-mep mep-id ] [ description description ]

        A test instance is configured.

      3. (Optional) Run loss-measure single-ended local-ratio-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

        Lower and upper thresholds are set for the near-end frame loss rate in proactive single-ended frame loss measurement in a specified test instance.

      4. (Optional) Run loss-measure single-ended remote-ratio-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

        Lower and upper thresholds are set for the far-end frame loss rate in proactive single-ended frame loss measurement in a specified test instance.

    3. On the receiver RMEP:

      Run loss-measure single-ended receive test-id test-id-value

      The RMEP is enabled to receive LMMs.

    4. On the initiator MEP:

      Run loss-measure single-ended continual send test-id test-id-value interval interval-value [ period period ]

      Proactive single-ended frame loss measurement is enabled.

    5. Run commit

      The configuration is committed.

Verifying the Configuration

After completing the configuration, run the display y1731 statistic-type single-loss [ test-id test-id-value ] [ count count-value ] command on the MEP that initiates single-ended frame loss measurement to check statistics about single-ended frame loss.

Copyright © Huawei Technologies Co., Ltd.