ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.11 hwAsFullNotify

Description

ASMNG/4/ASFULL: OID [oid] The AS capacity on the Parent is full. (AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE], Maximum AS Number=[INTEGER])

The number of ASs in the system reached the maximum value.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.11 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.
Maximum AS Number Indicates the maximum number of ASs.

Impact on the System

New ASs cannot connect to the system.

Possible Causes

The number of ASs in the system reached the maximum value.

Procedure

  1. Run the display as all command to check current online ASs.
  2. Delete unnecessary ASs.

    1. Run the display uni-mng as name as-name interface brief command to check the fabric port for the specified ASs to be deleted.
    2. Run the display interface eth-trunk eth-trunk-id command to check member interfaces of the Eth-Trunk to which the fabric port is bound.
    3. Run the interface interface-type interface-number command to enter the member interface view.
    4. Run the shutdown command to shut down the member interface.
    5. Log in to the AS to be deleted and run the undo uni-mng enable command in the user view to restore the AS to the standalone mode. After this command is executed, the AS restarts.

Related Information

None.