ASMNG/3/READ_PSK_FAIL: Failed to read the pre-shared
key.
Description
The AS failed to read the pre-shared key from the flash
memory.
Parameters
Parameter Name
Parameter Meaning
None
None
Possible Causes
Failed to obtain the DTLS pre-shared key from the
flash memory.
Procedure
Enable the AS to read the pre-shared key from the flash
memory again after this AS is restarted. For details about restarting
an AS, see "Restarting an AS" in the S2720, S5700, and S6700V200R019C10 Configuration Guide
- Device Management Configuration - SVF Configuration.
If the fault persists, a flash failure occurred. Replace
this AS. For details, see "Replacing an AS" in the S2720, S5700, and S6700V200R019C10 Configuration
Guide - Device Management Configuration - SVF Configuration.
If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.