Description

CLKMIB/4/SYSCLKWORKMODECHANGE: OID [oid] The work mode of system clock source change notification. (hwClockAttributeChassisIndex = [integer], hwClockChassisId = [integer], hwClockSourceOldWorkMode = [integer], hwClockAttributeSysClkLockMode = [integer])

The working mode of the system clock changed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.186.1.8.2 Warning equipmentAlarm(5)

Parameters

Name Meaning

[oid]

Indicates the MIB object ID of the alarm.

hwClockAttributeChassisIndex

Indicates the index of the chassis where the clock source resides. The index is always 1 for a single chassis.

hwClockChassisId

Indicates the ID of the chassis where the clock source resides.

hwClockSourceOldWorkMode

Indicates the old lock mode of the clock source.

The value can be:

  • free: Indicates the free mode.
  • hold: Indicates the hold mode.
  • normal: Indicates the normal mode.

hwClockAttributeSysClkLockMode

Indicates the lock mode of the system clock.

Impact on the System

If the working mode changes to hold or free, the clock accuracy will be affected and the services that depend on the clock signals may also be affected.

Possible Causes

  1. A new working mode was manually set.
  2. The clock source traced by the system clock was lost and there was no clock source available to be traced.

Procedure

  1. Run the display clock config command to check the operating mode of the clock source.

    • If the operating mode is free, it indicates that the clock source is in the free oscillation state. Then, go to Step 4.

    • If the operating mode is hold, it indicates that the clock source is in the hold state. Then, go to Step 4.

    • If the operating mode is normal, go to Step 2.

  2. Run the display clock source command to check whether the system clock has selected a clock source.

    • If the Current system trace source field is empty, it indicates that the clock source traced by the system clock is lost. Then, go to Step 4.

    • If the Current system trace source field displays a value (not empty), go to Step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.
Copyright © Huawei Technologies Co., Ltd.