CLKMIB_1.3.6.1.4.1.2011.5.25.186.1.8.25 hwClockSourceInputBelowThresholdResume

Description

CLKMIB/2/CLOCKSOURCEINPUTABOVETHRESHOLD:OID [oid] The SSM of input above or equal threshold notification. (hwClockAttributeChassisIndex = [integer], hwClockSrcCfgChassisIndex = [integer], hwClockSrcCfgSourceTypeIndex = [integer], hwClockSrcCfgSourceIndex = [integer], hwClockChassisId = [integer], hwClockPllId = [integer], hwClockAttributeInputThreshold = [integer], hwClockSrcCfgSourceSsm = [integer])

The input SSM level of the clock source restored to not below the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.186.1.8.25

Major

equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the MIB object ID of the alarm.

hwClockAttributeChassisIndex

This object indicates the index of the chassis where the clock source is located. In the case of a single chassis, the index is 1.

hwClockSrcCfgChassisIndex

This object indicates the index of the chassis where the clock source is located. In the case of a single chassis, the index is 1.

hwClockSrcCfgSourceTypeIndex

This object indicates the index of a clock source type.
  • bits(1): external clock source
  • ptp(2): PTP source
  • interface(3): interface clock source

hwClockSrcCfgSourceIndex

This object indicates the index of the clock source.

hwClockChassisId

This object indicates the ID of the chassis where the clock source resides.

hwClockPllId

This object indicates the PLL ID.
  • System(1): system PLL
  • sync2M-1(2): 2M PLL-1
  • sync2M-2(3): 2M PLL-2

hwClockAttributeInputThreshold

This object indicates the threshold for the input SSM level of an external clock source.

hwClockSrcCfgSourceSsm

This object indicates the SSM level of the clock source.
  • unk(0)
  • prc(2)
  • ssua(4)
  • ssub(8)
  • sec(11)
  • dnu(15)

Impact on the System

None.

Possible Causes

  • The SSM control function was disabled on the clock source.
  • An SSM level higher than or equal to the threshold was manually specified.
  • The input SSM level of the clock source was changed to be higher than or equal to the threshold.
  • No ESMC packets were received from the clock source.

Procedure

  1. This alarm is informational only, and no action is required.