DLDP/4/DETECTUNIDIRECT(t): OID [oid] The port is detected in Loop status. (IfIndex=[integer], IfName=[STRING])
A loop is detected on an interface due to incorrect fiber connection or a hub fault.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.173.3.3 | Warning | equipmentAlarm(5) |
Name | Meaning |
---|---|
[oid] | Indicates the MIB object ID of the alarm. |
IfIndex | Indicates the index of the interface where the loop alarm is generated. |
IfName | Indicates the name of the interface where the loop alarm is generated. |
The signals transmitted from the Tx end of an optical interface are received by the Rx end of the interface due the either of the following reasons:
If the DLDP port state field displays advertisement, the loop has been removed. Go to 4.
If the DLDP port state field displays loop, a loop link exists. Go to 2.
(1) If the fibers are corrected incorrectly or the hub fails, connect the fibers correctly or fix the hub fault, and go to 1.
(2) If the fibers are connected correctly and the hub connected to the interface is working properly, go to 3.