EOAM_Y1731/4/VLAN_1DM_EXCEED_THRESHOLD:OID [OID] The result of one-way delay-measure exceeded the threshold. (MdIndex=[GAUGE], MaIndex=[GAUGE], RemoteMacAddress=[OPAQUE], Timestamp=[TIMETICK], DelayValue=[GAUGE], ThresholdValue=[GAUGE])
In the VLAN networking where one-way frame delay measurement was configured and an expected alarm threshold was set, if the network delay exceeded the alarm threshold, an alarm was generated.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.136.1.6.23 | Warning | qualityOfServiceAlarm(3) |
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
MdIndex |
Index of the MD where a one-way frame delay alarm is generated |
MaIndex |
Index of the MA where a one-way frame delay alarm is generated |
RemoteMacAddress |
Source MAC address contained in the 1DM frame received by the local end from the remote end |
Timestamp |
Timestamp indicating the time when a one-way frame delay alarm is generated |
DelayValue |
Delay when a one-way frame delay alarm is generated |
ThresholdValue |
An alarm threshold for one-way frame delay measurement |
The device was enabled with one-way frame delay measurement and was configured with an alarm threshold, and the delay in unidirectional frame transmission exceeded the alarm threshold.
If the clocks of the two devices are synchronized, go to Step 3.
If the clocks of the two devices are not synchronized, go to Step 2.
If the alarm is cleared, go to Step 6.
If the alarm is not cleared, go to Step 5.
If there is a long delay, go to Step 4.
If there is no long delay, go to Step 5.
If the alarm is cleared, go to Step 6.
If the alarm is not cleared, go to Step 5.