EOAM_Y1731/4/VLAN_2DM_EXCEED_THRESHOLD:OID [OID] The result of two-way delay-measure exceeded the threshold. (MdIndex=[GAUGE], MaIndex=[GAUGE], RemoteMacAddress=[OPAQUE], Timestamp=[TIMETICK], DelayValue=[GAUGE], ThresholdValue=[GAUGE])
In the VLAN networking where two-way frame delay measurement was configured and the expected alarm threshold was set, if the network delay exceeded the set alarm threshold, an alarm was generated.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.136.1.6.25 | Warning | qualityOfServiceAlarm(3) |
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
MdIndex |
Index of the MD where a two-way frame delay alarm is generated |
MaIndex |
Index of the MA where a two-way frame delay alarm is generated |
RemoteMacAddress |
Source MAC address contained in the DMR frame received by the local end from the remote end |
Timestamp |
Timestamp indicating the time when a two-way frame delay alarm is generated |
DelayValue |
Delay when a two-way frame delay alarm is generated |
ThresholdValue |
An alarm threshold for two-way frame delay measurement |
The device was enabled with two-way frame delay measurement and was configured with an alarm threshold, and the delay in bidirectional frame transmission exceeded the alarm threshold.
If there is such a long delay, go to Step 2.
If there is no such a long delay, go to Step 3.
If the alarm is cleared, go to Step 4.
If the alarm is not cleared, go to Step 3.