ENTITYTRAP/1/ENTITYBRDTEMPALARM: OID [oid] Temperature rises over or falls below the warning alarm threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdValue=[INTEGER], EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])
The temperature of the board or chip is out of the normal range.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.2.10.13 |
Critical |
environmentalAlarm(6) |
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
Index |
Indicates the index. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
PhysicalName |
Indicates the name of the physical entity. |
EntityThresholdType |
Indicates the threshold type of the physical entity. |
EntityThresholdValue |
Indicates the threshold value of the physical entity. |
EntityThresholdCurrent |
Indicates the current value of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
Error Code |
Possible Causes |
Procedure |
---|---|---|
143617 |
The temperature of the board is higher than the upper threshold, the possible causes are as follows:
|
|
143619 |
The ambient temperature is too low, causing the device temperature to be lower than the lower threshold. |
Measure the ambient temperature. If the ambient temperature is too low, use air conditioners or heaters to increase the temperature. If the ambient temperature is normal, the lower threshold of the temperature may be too high. Run the temperature threshold slot slotid lower-limit lower upper-limit upper command to decrease the lower threshold of the temperature. |
143624 143626 |
The chip temperature is higher than the upper limit. The possible causes are as follows:
|
Same as the error code 143617. |
143625 |
The ambient temperature is too high. As a result, the CPU temperature is too high. The device automatically restarts later. |
Same as the error code 143617. |