ENTITYTRAP/4/ENTITYBRDTEMPRESUME: OID [oid] The temperature is restored to a normal range. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdValue=[INTEGER], EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])
The temperature of the board or chip is restored to the allowed range.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.2.10.14 |
Warning |
environmentalAlarm(6) |
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
Index |
Indicates the index. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
PhysicalName |
Indicates the name of the physical entity. |
EntityThresholdType |
Indicates the threshold type of the physical entity. |
EntityTrapEntType |
Indicates the alarm type of the physical entity. |
EntityThresholdValue |
Indicates the threshold value of the physical entity. |
EntityThresholdCurrent |
Indicates the current value of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
Error Code |
Description |
---|---|
143617 |
The temperature of the board is higher than the upper threshold. |
143619 |
The ambient temperature is too low, causing the device temperature to be lower than the lower threshold. |
143624 143626 |
The chip temperature is higher than the upper limit. The possible causes are as follows:
|
143625 |
The ambient temperature is too high. As a result, the CPU temperature is too high. The device automatically restarts later. |