ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.10.14 hwBrdTempResume

Description

ENTITYTRAP/4/ENTITYBRDTEMPRESUME: OID [oid] The temperature is restored to a normal range. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdValue=[INTEGER], EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])

The temperature of the board or chip is restored to the allowed range.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.219.2.10.14

Warning

environmentalAlarm(6)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Index

Indicates the index.

EntityPhysicalIndex

Indicates the index of the physical entity.

PhysicalName

Indicates the name of the physical entity.

EntityThresholdType

Indicates the threshold type of the physical entity.

EntityTrapEntType

Indicates the alarm type of the physical entity.

EntityThresholdValue

Indicates the threshold value of the physical entity.

EntityThresholdCurrent

Indicates the current value of the physical entity.

EntityTrapFaultID

Indicates the error code.

Impact on the System

None.

Possible Causes

The temperature of the board or chip is restored to the allowed range.

Procedure

  • This alarm is informational and no action is required. The error codes are as follows:

    Error Code

    Description

    143617

    The temperature of the board is higher than the upper threshold.

    143619

    The ambient temperature is too low, causing the device temperature to be lower than the lower threshold.

    143624

    143626

    The chip temperature is higher than the upper limit. The possible causes are as follows:
    • The chassis is not ventilated well, which causes heat unable to be dissipated.

    • Rear card slots are not covered with filler panels.

    • The ambient temperature is high.

    • There are not enough fans in the switch.

    • One or more fans in the switch have failed.

    143625

    The ambient temperature is too high. As a result, the CPU temperature is too high. The device automatically restarts later.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >