ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136201

Description

ENTITYTRAP/3/OPTTEMALM:OID [oid] The temperature of optical exceeds the upper alarm threshold or falls below the lower alarm threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

The optical module temperature exceeds the upper threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.4.5 Minor equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
Index Indicates an index.
EntityPhysicalIndex Indicates a physical entity index.
PhysicalName Indicates a physical entity name.
EntityTrapFaultID Indicates an error code.
EntityTrapReasonDescr Indicates the alarm reason.

Impact on the System

The optical module may fail to work properly, affecting services.

Possible Causes

The possible causes include:
  • The device is not ventilated well, which causes heat unable to be dissipated.

  • The ambient temperature of the device is too high.

  • The number of fans on the device is insufficient.

  • Fans on the device are faulty.

Procedure

  1. Clean the air vent and check whether the alarm is cleared.
    • If so, the alarm handling ends.
    • If not, go to step 2.
  2. Reduce the ambient temperature and check whether the alarm is cleared.
    • If so, the alarm handling ends.
    • If not, go to step 3.
  3. Run the display fan command to check the fan status. Ensure that fans are working normally and check whether the alarm is cleared.
    • If so, the alarm handling ends.
    • If not, go to step 4.
  4. Add fans and check whether the alarm is rectified.
    • If so, the alarm handling ends.
    • If not, collect alarm and configuration information, and contact technical support personnel.