ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136202

Description

ENTITYTRAP/3/OPTTEMALM:OID [oid] The temperature of optical exceeds the upper alarm threshold or falls below the lower alarm threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

The optical module temperature is below the lower threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.4.5 Minor equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
Index Indicates an index.
EntityPhysicalIndex Indicates a physical entity index.
PhysicalName Indicates a physical entity name.
EntityTrapFaultID Indicates an error code.
EntityTrapReasonDescr Indicates the alarm reason.

Impact on the System

The optical module may fail to work properly, affecting services.

Possible Causes

The ambient temperature is too low.

Procedure

  • Run the display transceiver slot slot-id verbose command to check whether the temperature of the optical module is within the allowed range.

    • If the temperature of the optical module is within the allowed range, collect alarms, logs, and configurations, and contact technical support personnel.
    • If the temperature of the optical module is out of the allowed range, replace the optical module.