IFPDT/1/CRCRATEEXCEED: OID [OID] The interface CRC error rate exceeded the trap threshold, which may affect forwarding. Handle it as soon as possible. (InterfaceIndex=[INTEGER], InterfaceName=[OCTET], CrcRate=[OCTET], TrapThreshold=[OCTET])
The rate of receiving CRC error packets equals or exceeds 1000 packets per second.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.2.157.18 | Critical | qualityOfServiceAlarm(3) |
Name | Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
InterfaceIndex |
Indicates the interface index. |
InterfaceName |
Indicates the interface name. |
CrcRate |
Indicates the current rate of receiving CRC error packets. |
TrapThreshold |
Indicates the alarm threshold for the rate of receiving CRC error packets. |
After the stacking function is enabled on the switch, the rate of receiving CRC error packets by an interface equals or exceeds 1000 packets per second. The possible causes include:
Cause 1:
The optical module is faulty.
Cause 2:
The optical fiber is faulty.