< Home

MGMD_1.3.6.1.4.1.2011.5.25.149.3.3.13 hwMgmdTotalLimitThresholdExceedClear

Description

MGMD/3/hwMgmdTotalLimitThresholdExceedClear:OID [oid] IGMP or MLD total entries count in all instances fell below the lower threshold. (hwMgmdNotificationAddressType=[integer], hwMgmdTotalLimitCurrentCount=[integer], hwMgmdTotalLimitThreshold=[integer]%, hwMgmdTotalEntries=[integer])

The proportion of global IGMP/MLD entries created to the maximum global IGMP/MLD entries allowed fell below the lower alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.149.3.3.13

Minor

communicationsAlarm

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwMgmdNotificationAddressType

Group address type:
  • 1: IPv4 address (IGMP)

  • 2: IPv6 address (MLD)

hwMgmdTotalLimitCurrentCount

Number of global IGMP/MLD entries created

hwMgmdTotalLimitThreshold

Alarm threshold for global IGMP/MLD entries

hwMgmdTotalEntries

Maximum number of global IGMP/MLD entries allowed

Impact on the System

Services will not be affected.

Possible Causes

The proportion of global IGMP/MLD entries created to the maximum global IGMP/MLD entries allowed fell below the lower alarm threshold.

Procedure

  1. This message is informational only, and no action is required.

Related Information

None