< Home

MGMD_1.3.6.1.4.1.2011.5.25.149.3.3.15 hwMgmdHostStarGThresholdExceedClear

Description

MGMD/3/hwMgmdHostStarGThresholdExceedClear:OID [oid] IGMP or MLD total (*, G) entries on the host side of all instances count fell below the lower threshold. (hwMgmdNotificationAddressType=[integer], hwMgmdHostStarGCurrentCount=[integer], hwMgmdHostStarGThreshold=[integer]%, hwMgmdHostStarGTotalCount=[integer])

The (*, G) entry usage of all instances fell below the specified lower alarm threshold on the user-side IGMP/MLD device.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.149.3.3.15

Minor

communicationsAlarm

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwMgmdNotificationAddressType

Group address type:
  • 1: IPv4 address (IGMP)

  • 2: IPv6 address (MLD)

hwMgmdHostStarGCurrentCount

Number of existing (*, G) entries of all instances on the user-side IGMP/MLD device

hwMgmdHostStarGThreshold

Upper and lower alarm thresholds for the (*, G) entry usage of all instances on the user-side IGMP/MLD device

hwMgmdHostStarGTotalCount

Maximum limit of total number of (*, G) entries of all instances on the user-side IGMP/MLD device

Impact on the System

Services will not be affected.

Possible Causes

The (*, G) entry usage of all instances fell below the specified lower alarm threshold on the user-side IGMP/MLD device.

Procedure

  1. This message is informational only, and no action is required.

Related Information

None