POE/4/PDINVALIDCLASS: OID [oid] PD with invalid IEEE class and power denied. (IfIndex=[INTEGER], Interface="[OCTET]")
The system detects that the PD class is invalid.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.195.40.10 | Warning | communicationsAlarm(2) |
Name | Meaning |
---|---|
oid | Indicates the MIB object ID of the alarm. |
IfIndex | Indicates the interface index. |
Interface | Indicates the interface name. |
Cause 1:
The PD may not comply with standards, whereas the switch supports 802.3af and 802.3at. In this case, the PD class cannot be identified by the switch.
Cause 2:
The PD hardware is faulty.
Cause 3:
The PoE chip of the device is faulty.
If so, the alarm handling ends.
If not, go to step 2.
If so, the alarm handling ends.
If not, collect alarm information and configuration information, and then contact technical support personnel.