< Home

POE_1.3.6.1.4.1.2011.5.25.195.40.11 hwPoePdClassOvercurrent

Description

POE/4/PDCLASSOVERCURRENT: OID [oid] has detected a classfication overcurrent PD and power denied. (IfIndex=[INTEGER], Interface="[OCTET]")

The system detects that overcurrent occurs during PD classification.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.195.40.11

Warning

communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

IfIndex

Indicates the interface index.

Interface

Indicates the interface name.

Impact on the System

Services are not affected.

Possible Causes

The PD does not comply with standards.

Procedure

  1. Run the poe high-inrush enable slot slot-id command in the system view to allow high inrush current during power-on and then check whether the alarm is cleared.

    If so, the alarm handling ends.

    If not, go to step 2.

  2. Replace the PD with a standard PD and then check whether the alarm is cleared.

    If so, the alarm handling ends.

    If not, collect alarm information and configuration information, and then contact technical support personnel.

Related Information

None