POE/4/PWRUTITHRESH: PSE is overdrawing power. (SlotID=[ULONG])
Description
The total PoE power consumption is greater than or
equal to the alarm threshold.
Parameters
Parameter Name
Parameter Meaning
SlotID
Indicates the ID of
the slot where the log is generated.
Possible Causes
The total power consumption of all the PDs is greater
than or equal to the alarm threshold.
Procedure
Check whether the power consumption of the PDs is within
the accepted range.
If so, go to step 2.
If not, go to step 3.
Run the poe power-threshold command to change the alarm threshold for PoE power consumption
percentage.
Replan the network based on the system external power supply
capability. Run the poe priority command to increase
the priority of important PDs to prevent their power from being occupied
by other PDs. Power off the PDs that are not required to ensure system
reliability.