SEP/6/RCV_CFM_FAULT

Message

SEP/6/RCV_CFM_FAULT:The SEP receives an error notification from the CFM. (Segment ID=[ULONG], Port Name=[STRING], Fault State=[STRING])

Description

After the SEP segment was associated with CFM, CFM sends a fault notification to the SEP segment through the OAM module when detecting a connectivity fault or a fault recovery event.

Parameters

Parameter Name Parameter Meaning
Segment ID ID of the SEP segment
Port Name Name of the interface added to the SEP segment
Fault State Fault state

Possible Causes

Cause 1: After the SEP segment was associated with CFM, CFM detected that the fault was rectified.

Cause 2: After the SEP segment was associated with CFM, CFM detected a connectivity fault.

Procedure

  1. Cause 1: After the SEP segment was associated with CFM, CFM detected that the fault was rectified.

    This log message indicates a normal situation, and no action is required.

  2. Cause 2: After the SEP segment was associated with CFM, CFM detected a connectivity fault.
    1. Run the display cfm remote-mep command to view the CFM Status field.

      • If the CFM Status field is displayed as Up, it indicates that the CC link is normal. In this case, go to b.
      • If the CFM Status field is displayed as Up, it indicates that CFM detects a CC link fault. In this case, go to b.

    2. Collect configurations and log messages, and then contact technical support personnel.