SRM/3/RXPOWER_EXCEEDMAJOR

Message

SRM/3/RXPOWER_EXCEEDMAJOR:Optical module in interface [STRING] exception, Rx power is too high.

Description

The receive power of an optical module is too high.

Parameters

Parameter Name Parameter Meaning
STRING Indicates an interface name.

Possible Causes

The receive optical power of the optical module exceeds the upper threshold.

Procedure

  1. Run the display transceiver command to check whether the receive power (RX Power) of the optical module exceeds the upper threshold (RX Power High Threshold).
    • If so, go to step 2.
    • If not, go to step 3.
  2. Check whether the receive power upper threshold of the optical module is within the acceptable range.
    • If so, run the transceiver diagnosis threshold rx-power command to change the receive power upper threshold of the optical module.
    • If not, go to step 3.
  3. Collect log information and configuration information, and then contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.