Function

The alarm-restriction period command configures the period of alarm suppression on an AP.

The undo alarm-restriction period command restores the default period of alarm suppression for an AP.

The default alarm suppression period is 60 seconds on an AP.

Format

alarm-restriction period period

undo alarm-restriction period

Parameters

Parameter Description Value

period

Specifies the period of alarm suppression for an AP. The value is an integer that ranges from 10 to 300, in seconds.

Views

AP system profile view

Default Level

2: Configuration level

Usage Guidelines

You can run the ap alarm-restriction period command to configure the period of alarm suppression for an AP. The AP reports an alarm only one time in the specified period if the alarm is repeatedly generated.

Example

# Set the period of alarm suppression to 200 seconds for an AP.

<HUAWEI> system-view
[HUAWEI] wlan
[HUAWEI-wlan-view] ap-system-profile name ap-system1
[HUAWEI-wlan-ap-system-prof-ap-system1] alarm-restriction period 200