< Home

assign group-speed

Function

The assign group-speed command sets the maximum rate of interfaces in a MultiGE interface group.

The undo assign group-speed command restores the default maximum rate of interfaces in a MultiGE interface group.

By default, you can run the display device group-speed configuration command to check the maximum rate of a MultiGE interface based on the BaseSpeed field in the command output.

This command is supported only on the following switch models:

S5732-H24UM2CC and S5732-H48UM2CC

Format

assign group-speed [ slot slot-id ] group group-number speed

undo assign group-speed [ slot slot-id ] group group-number

Parameters

Parameter Description Value

slot slot-id

Specifies a slot ID.

In a stack, if no slot ID is specified, the maximum rate of interfaces in the MultiGE interface group on the master switch is configured.

The value must be set according to the device configuration.

group group-number

Specifies the number of a MultiGE interface group.

The value is an integer and must be set according to the device configuration.

Every 12 MultiGE interfaces form a MultiGE interface group. The number of MultiGE interface groups determines the value range. For example, if a device has 24 MultiGE interfaces, the value is 0 or 1.

speed

Specifies the maximum rate of a MultiGE interface.

The value is of the enumerated type:

  • 1000
  • 2500
  • 5000
  • 10000

The unit is bit/s.

NOTE:
  • The value range of this parameter depends on the loaded license control item.
  • The specified MultiGE interface rate cannot be lower than the default MultiGE interface rate.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

On the S5732-H24UM2CC and S5732-H48UM2CC, every 12 MultiGE interfaces form a MultiGE interface group. To set the maximum rate of interfaces in a specified MultiGE interface group, run the assign group-speed command. The maximum rates of interfaces in the same MultiGE interface group are the same, and the maximum rates of interfaces in different MultiGE interface groups can be different.

Precautions

  • This command takes effect only on the device to which license control items are loaded. For details about how to use license control items, see Other: How Can I Increase the Rate of Ports on the S5732-H24UM2CC or S5732-H48UM2CC? in the S1720, S5700, and S6700 Series Switches License Usage Guide.
  • After you run the assign group-speed command to set the maximum rate of interfaces in a MultiGE interface group, restart the switch to make the configuration take effect. If you have run the assign group-speed command multiple times to set the maximum rate of interfaces in multiple MultiGE interface groups, restart the switch to make these configurations take effect simultaneously.
  • After the assign group-speed command is run, the maximum rate of interfaces in a MultiGE interface group is restored to the default value if factory settings are restored with one click.
  • After the license for a MultiGE interface group expires, if the device is restarted or factory settings are restored with one click, the maximum rate of interfaces in the MultiGE interface group is restored to the default value.

Example

# Set the maximum rate of interfaces in MultiGE interface group 0 to 10000 bit/s.

<HUAWEI> system-view
[HUAWEI] assign group-speed group 0 10000