< Home

authentication associate alarm-restrain period

Function

The authentication associate alarm-restrain period command sets a suppression period for alarms that an authentication access device generates due to excess associated users.

The undo authentication associate alarm-restrain period command restores the default setting.

By default, an authentication access device suppresses such alarms for 300 seconds.

Format

authentication associate alarm-restrain period period-value

undo authentication associate alarm-restrain period

Parameters

Parameter

Description

Value

period-value

Specifies a suppression period for alarms that an authentication access device generates due to excess associated users.

The value is an integer that ranges from 60 to 604800, in seconds.

Views

System view

Default Level

1: Monitoring level

Usage Guidelines

Usage Scenario

After an authentication access device is enabled to suppress alarms that are generated due to excess associated users using the authentication associate alarm-restrain enable command, run the authentication associate alarm-restrain period command to set a suppression period for these alarms. The device then does not generate alarms of the same type within the suppression period.

Precautions

This command is supported only on authentication access devices.

Example

# Set the suppression period to 600s for alarms that an authentication access device generates due to excess associated users.

<HUAWEI> system-view
[HUAWEI] authentication associate alarm-restrain period 600