The authentication associate alarm-restrain enable command enables an authentication access device to suppress alarms that are generated due to excess associated users.
The undo authentication associate alarm-restrain enable command disables alarm suppression.
By default, an authentication access device is enabled to suppress alarms that are generated due to excess associated users.
authentication associate alarm-restrain enable
undo authentication associate alarm-restrain enable
Usage Scenario
If associated users fail to log in to an authentication access device due to the configured limitation on the access number, the device generates alarms about the login failure event.
These alarms consume device resources and affect system performance. To prevent the device from generating too many repeated alarms in a short period, run the authentication associate alarm-restrain enable command to enable suppression on these alarms. The device then does not generate alarms of the same type within a specified suppression period (set using the authentication associate alarm-restrain period command).
Precautions
This command is supported only on authentication access devices.