The device temperature is too high if high temperature alarm is generated on the device. The system adjusts the fan speed automatically to help ensure that the device temperature is within the normal range.
The temperature range of a device varies according to device models. For details, see "Specifications" in the Hardware Description - Chassis.
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm 140544 ENTITYTRAP/1/ENTITYBRDTEMPALARM: OID [oid] Temperature rise over or fall below the warning alarm threshold.(Index=[INTEGER], ThresholdEntityPhysicalIndex=[INTEGER],EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdValue=[INTEGER],EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])
SRM_1.3.6.1.4.1.2011.5.25.129.2.2.1 hwTempRisingAlarm SRM/3/TEMPRISINGALARM:OID [OID] temperature over major threshold .(EntityPhysicalIndex=[INTEGER], BaseThresholdEntry_entPhys icalIndex=[INTEGER], BaseThresholdEntry_hwBaseThresholdType=[INTEGER], BaseThresholdEntry_hwBaseThresholdIndex=[INTEGER], Ba seTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalName=[OCTET], BaseThresho ldValue=[INTEGER], BaseThresholdUnit=[INTEGER], BaseThresholdHighWarning=[INTEGER], BaseThresholdHighCritical=[INTEGER])