You can set optical power alarm so that the device generates alarms if the transmit or receive power of an optical module exceeds a threshold. An alarm may indicate that the optical module is faulty.
The default optical power alarm thresholds of an optical module are fixed and cannot be changed. These thresholds are determined through extensive testing and verification. You can configure alarm thresholds but they must be within the default range. However, this is not recommended. If an optical power alarm is generated, the first step of troubleshooting is to check the optical module and connected fibers.
You are advised to use Huawei-certified optical modules. If non-Huawei-certified optical modules are used, incorrect optical module information may be obtained during the query of optical power information.
Conventional, manufacturing, and alarm information about the optical module on a specified interface is displayed.
Diagnostic information about the optical module on a specified interface is displayed.
The system view is displayed.
The interface view is displayed.
Upper and lower alarm thresholds are set for the receive power of the optical module on the interface.
Upper and lower alarm thresholds are set for the transmit power of the optical module on the interface.