After logs are output to a user terminal, you can view logs on the user terminal (host from which you log in to the device through Telnet) to monitor device running.
The system view is displayed.
A channel through which logs are output to a user terminal is specified.
By default, the switch uses channel 1 to output logs to a user terminal.
A rule for outputting logs to a channel is set.
By default, channel 1 is enabled to output logs and the lowest log severity is warning.
Return to the user view.
Display of logs, traps, and debugging message output is enabled on the user terminal.
By default, console display is enabled and terminal display is disabled.
Log display is enabled on the user terminal.
By default, log display is enabled on the user terminal.