BFD parameters include the minimum intervals for sending and receiving BFD packets, and local BFD detection multiplier. The parameters affect BFD session setup.
You can adjust the local detection time according to the network situation. On an unstable link, if a small detection time is used, a BFD session may flap. You can increase the detection time of the BFD session.
Actual interval for the local device to send BFD packets = MAX {locally configured interval for sending BFD packets, remotely configured interval for receiving BFD packets}
Actual interval for the local device to receive BFD packets = MAX {remotely configured interval for sending BFD packets, locally configured interval for receiving BFD packets}
Local detection time = Actual interval for receiving BFD packets x Remotely configured BFD detection multiplier
Perform the following steps on the ingress node.
The system view is displayed.
The BFD view is displayed.
The interval for sending LSP ping packets is adjusted.
By default, the interval at which LSP ping packets are sent in a dynamic BFD session is 60 seconds.
Exit from the BFD view.
The MPLS view is displayed.
BFD time parameters are set.