< Home

Enabling MPLS TE

Context

Perform the following configurations on each node of the MPLS TE tunnel.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run mpls

    The MPLS view is displayed.

  3. Run mpls te

    MPLS TE is enabled on the node globally.

  4. Run quit

    Return to the system view.

  5. Run interface interface-type interface-number

    The view of the interface is displayed.

  6. (Optional) On an Ethernet interface, run undo portswitch

    The interface is switched to Layer 3 mode.

    By default, an Ethernet interface works in Layer 2 mode.

    Only the S5720-EI, S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-EI, S6720-HI, S6720S-EI, S6730-H, S6730S-H, S6730-S, and S6730S-S support switching between Layer 2 and Layer 3 modes.

  7. Run mpls

    The MPLS is enabled on the interface.

  8. Run mpls te

    The MPLS TE is enabled on the interface.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.