< Home

Configuring the NQA Client to Send Traps When a Probe Fails

Context

Path jitter test test does not support the traps for probe failures.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run nqa test-instance admin-name test-name

    The NQA view is displayed.

  3. Run send-trap probefailure

    The NQA client is configured to send traps when a probe fails.

    By default, the NQA client sends no trap when a probe fails.

  4. Run probe-failtimes times

    The threshold on the traps sent after the probe fails is configured. The threshold specifies the maximum number of continuous probe failures for the NQA test instance.

    By default, a trap is sent for each probe failure.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >