Based on the type of link between a PE and a CE, a VSI is bound to an AC interface on the PE in one of the following modes:
Binding the VSI with the GE interface, 25GE interface, 40GE interface, 100GE interface, MultiGE interface, or XGE interface when the PE and the CE are connected through the Ethernet interface
Binding the VSI with the GE sub-interface, 25GE sub-interface, 40GE sub-interface, 100GE sub-interface, MultiGE sub-interface, or XGE sub-interface when the PE and the CE are connected through the Ethernet sub-interface
Binding the VSI with the VLANIF interface when the PE and the CE are connected through the VLANIF interface
Binding the VSI with the Eth-Trunk when the PE and the CE are connected through the Eth-Trunk interface
Binding the VSI with the Eth-Trunk sub-interface when the PE and the CE are connected through the Eth-Trunk sub-interface
The sub-interfaces can be Dot1q sub-interfaces, QinQ sub-interfaces, VLAN mapping sub-interfaces, or VLAN stacking sub-interfaces. For details on how to access the VPLS through a sub-interface, see Configuring a Dot1q Termination Sub-interface and Connecting It to an L2VPN and Configuring a QinQ Termination Sub-interface and Connecting It to an L2VPN in "VLAN Termination Configuration" in the S2720, S5700, and S6700 V200R019C10 Configuration Guide - Ethernet Switching.
When XGE, GE, 25GE, MultiGE, 40GE, 100GE, or Eth-Trunk interfaces are used as AC interfaces, the outer Tags carried in the packets sent from the AC to the PW are U Tags (inserted by user devices, which are meaningless to the SP) by default.
When VLANIF interfaces are used as AC interfaces, the outer Tags carried in the packets sent from the AC to the PW are P Tags (inserted by SP devices, which are used to differentiate user traffic) by default.
If the VLANIF interface configured based on a PVID is bound to a VSI, interfaces corresponding to this PVID cannot forward Layer 2 protocol BPDUs.
In the VPLS application, different CEs are transparently connected in the same LAN segment through VSIs, and the IP addresses of the CEs must be different.
When used on an AC-side interface, the qinq protocol command enables the system to identify incoming packets and Tag outgoing packets with the TPID. The TPID must use the default value 8100. Do not change the TPID.
If an interface is used as a VPLS AC-side interface and a multicast inbound interface at the same time, multicast data cannot be forwarded normally on this interface. (S5720-HI, S5730-HI, S5731-H, S5731S-H, S5732-H, S6720-HI, S6730S-H, and S6730-H do not have this restriction.)
Do as follows on the PEs at both ends of a PW:
Do as follows on the PEs at both ends of a PW:
Do as follows on the PEs at both ends of a PW:
Do as follows on the PEs at both ends of a PW:
Do as follows on the PEs at both ends of a PW: