< Home

Naming Conventions

Figure 1 S2700 switch naming conventions

The uplink and downlink ports mentioned in this document refer to the recommended usage of the port, and do not indicate that the corresponding port can be used only for the downlink or uplink.

Table 1 S2700 switch naming convention description

Identifier

Description

A

Switch

B

  • 6: 10GE downlink ports
  • 5: GE downlink ports
  • 3: Layer 3 switch with 100M downlink ports
  • 2: Layer 2 switch with 100M downlink ports

C

7: switch for enterprise networks

D

Product sub-series (such as 00 or 10)

E

Maximum number of ports

F

Uplink port type:

  • TP: The uplink ports of the product are GE combo ports or independent GE electrical and optical ports.

  • P: The uplink ports of the product are fixed GE optical ports.

G

Power over Ethernet (PoE) model

NOTE:

If the product name does not contain this field, the switch does not support PoE.

H

Level type:

  • LI: lightweight version
  • SI: standard version

  • EI: enhanced version

  • HI: high-level version, which supports high-performance operation, administration, and maintenance (OAM) and built-in real-time clock (RTC)

I

Power supply type:
  • AC: switch using alternating current power supply

  • ACF: switch using AC power supply and having a built-in high-power PoE power module

  • ACL or L: switch using AC power supply and having a built-in low-power PoE power module

  • DC: switch using direct current power supply

Figure 2 S5700 switch naming conventions (applicable to versions earlier than V200R013C02)

The device names in this figure are used as examples and do not represent specific devices.

The uplink and downlink ports mentioned in this document refer to the recommended usage of the port, and do not indicate that the corresponding port can be used only for the downlink or uplink.

Table 2 S5700 switch naming convention description (applicable to versions earlier than V200R013C02)

Identifier

Description

A

Switch

B

  • 6: 10GE downlink ports
  • 5: GE downlink ports
  • 3: Layer 3 switch with 100M downlink ports
  • 2: Layer 2 switch with 100M downlink ports

C

7: switch for enterprise networks

D

Product sub-series (such as 00 or 10)

E

  • S: channel distribution model

  • SV2: enhanced channel distribution model

  • I: model supporting a wide temperature range

F

Maximum number of ports

NOTE:

On an S5710-EI switch (such as S5710-28C-EI), this field indicates the maximum number of fixed ports on the switch.

G

Uplink port type:

  • C: The product supports extended cards and its uplink ports are provided by an extended card or are fixed 10GE ports.

  • PC: The product supports extended cards and its uplink ports are provided by an extended card or are fixed GE ports.

  • X: The product has fixed 10GE uplink ports.

  • TP: The uplink ports of the product include combo ports consisting of electrical and optical ports.

  • P: The uplink ports of the product are fixed GE optical ports.

NOTE:

If the product name does not contain this field, the switch has no uplink port.

H

  • PWR: The product supports Power over Ethernet (PoE).

  • PWH: The product supports PoE++.

NOTE:

If the product name does not contain this field, the switch does not support PoE.

I

Level type:

  • LI: lightweight version
  • SI: standard version

  • EI: enhanced version

  • HI: high-level version, which supports high-performance operation, administration, and maintenance (OAM) and built-in real-time clock (RTC)

J

Downlink port type:
  • 24S: 24 downlink SFP optical ports
  • 48CS: 48 downlink compact SFP (CSFP) optical ports
NOTE:

If the product name does not contain this field, all downlink ports of the switch are electrical ports.

K

Power supply type:
  • AC: switch using AC power supply

  • AC1 or ACF: switch using AC power supply and supporting high-power PoE power modules

  • ACL: switch using AC power supply and having a built-in low-power PoE power module

  • DC: switch using DC power supply

  • BAT: battery LAN switch

NOTE:

Some product models that support pluggable power modules are sold with AC or DC power modules (standard configuration), and their product names contain "-AC" or "-DC". However, the silkscreen or nameplate on the chassis does not contain "-AC" or "-DC".

For example, the S5720-56C-HI supports pluggable AC and DC power modules. If its standard configuration includes AC power modules, its product name is S5720-56C-HI-AC, but the name on its silkscreen or nameplate is still S5720-56C-HI.

Figure 3 S5700 switch naming conventions (applicable to V200R013C02 and later versions)

The device names in this figure are used as examples and do not represent specific devices.

The uplink and downlink ports mentioned in this document refer to the recommended usage of the port, and do not indicate that the corresponding port can be used only for the downlink or uplink.

Table 3 S5700 switch naming convention description (applicable to V200R013C02 and later versions)

Identifier

Description

A

Product type (1 character)

The value is fixed at S, indicating that the device is an S series switch.

B

Role on the network (1 character)

  • 6: aggregation switch
  • 5: access switch

C

Market positioning (1 character)

7: switch for enterprise networks

D

Product sub-series (2 characters)

The left character indicates the generation, for example, S5720 and S5730. The right character indicates switches of the same series with different specifications, for example, S5720 and S5721.

E

Industry identifier (0 to 2 characters)
  • By default, this field is left empty.
  • S: channel distribution model

F

Level type (1 character)

  • H: high-level
  • M: enhanced
  • S: standard
  • L: lightweight

G

Number of downlink ports (1 or 2 characters)

H

Downlink port type (1 or 3 characters)

  • T: GE electrical port
  • P: GE electrical port, supporting PoE+
  • UM: MultiGE electrical port, supporting PoE++
  • XUM: MultiGE electrical port or 10GE optical port, supporting PoE++
  • X: 10GE optical port
  • S: GE optical port

I

Number of uplink ports (1 character)

J

Uplink port type (1 character)

  • S: GE optical port
  • X: 10GE optical port
  • C: 100GE optical port
  • Q: 40GE optical port

K

Support for pluggable cards (0 or 1 character)

  • Empty: The switch does not support pluggable cards.
  • C: The switch supports pluggable cards.

L

Special function type (0 or 1 characters)

  • I: The switch supports a wide temperature range.
  • M: The switch supports monitoring functions.

M

Power module type (0 to 2 characters)

  • Empty: The switch uses pluggable power modules.
  • A: The switches are sold with AC power module or with built-in AC power.
  • D: The switches are sold with DC power module.
NOTE:

This convention is not applicable to the S5735-S4T2X-IA150G1 and S5735-S8P2X-IA200G1.

Figure 4 S6700 switch naming conventions (applicable to versions earlier than V200R013C02)

The device names in this figure are used as examples and do not represent specific devices.

The uplink and downlink ports mentioned in this document refer to the recommended usage of the port, and do not indicate that the corresponding port can be used only for the downlink or uplink.

Table 4 S6700 switch naming convention description (applicable to versions earlier than V200R013C02)

Identifier

Description

A

Switch

B

  • 6: 10GE downlink ports
  • 5: GE downlink ports
  • 3: Layer 3 switch with 100M downlink ports
  • 2: Layer 2 switch with 100M downlink ports

C

7: Enterprise series switch

D

Product sub-series (such as 00 or 10)

E

S: channel distribution model

F

Maximum number of ports

G

Uplink port type:

  • C: The product supports extended cards and its uplink ports are provided by an extended card or are fixed QSFP+ ports.

  • Q: Uplink ports of the product are fixed QSFP+ ports.

  • X: The product has fixed 10GE uplink ports.

  • L: Uplink ports of the product are 100GE QSFP28 ports.

NOTE:

If the product name does not contain this field, the switch has no uplink port.

H

PWH: The product supports PoE++.

NOTE:

If the product name does not contain this field, the switch does not support PoE.

I

Level type:

  • LI: lightweight version
  • SI: standard version

  • EI: enhanced version

  • HI: high-level version, which supports high-performance operation, administration, and maintenance (OAM) and built-in real-time clock (RTC)

J

Downlink port type:
  • 24S: 24 downlink SFP+ optical ports
  • 48S: 48 downlink SFP+ optical ports

K

Power supply type:
  • AC: switch using alternating current power supply

  • DC: switch using direct current power supply

NOTE:

If S6720-EI, S6720-SI, and S6720S-SI switches are sold with pluggable AC or DC power modules in standard configuration, their product model names contain "-AC" or "-DC." However, the silkscreens and nameplates on the switches do not contain "-AC" or "-DC."

Figure 5 S6700 switch naming conventions (applicable to V200R013C02 and later versions)

The device names in this figure are used as examples and do not represent specific devices.

The uplink and downlink ports mentioned in this document refer to the recommended usage of the port, and do not indicate that the corresponding port can be used only for the downlink or uplink.

Table 5 S6700 switch naming convention description (applicable to V200R013C02 and later versions)

Identifier

Description

A

Product type (1 character)

The value is fixed at S, indicating that the device is an S series switch.

B

Role on the network (1 character)

  • 6: aggregation switch
  • 5: access switch

C

Market positioning (1 character)

7: Enterprise series switch

D

Product sub-series (2 characters)

The left character indicates the generation, for example, S6720 and S6730. The right character indicates switches of the same series with different specifications, for example, S6720 and S6721.

E

Industry identifier (0 to 2 characters)
  • By default, this field is left empty.
  • S: channel distribution model

F

Level type (1 character)

  • H: high-level
  • M: enhanced
  • S: standard

G

Number of downlink ports (1 or 2 characters)

H

Downlink port type (1 character)

  • T: GE electrical port
  • P: GE electrical port, supporting PoE+
  • X: 10GE optical port

I

Number of uplink ports (1 character)

J

Uplink port type (1 character)

  • S: GE optical port
  • X: 10GE optical port
  • C: 100GE optical port
  • Q: 40GE optical port

K

Support for pluggable cards (0 or 1 character)

  • Empty: The switch does not support pluggable cards.
  • C: The switch supports pluggable cards.

L

Power module type (0 to 2 characters)

  • Empty: The switch uses pluggable power modules.
  • A: The switches are sold with AC power module.
  • D: The switches are sold with DC power module.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.