Parameter | Description | Value |
---|---|---|
all |
Displays information about all air scan profiles. |
- |
name profile-name |
Displays information about a specified air scan profile. |
The air scan profile name must already exist. |
You can run the display air-scan-profile command to view information about air scan profiles.
# Display information about all air scan profiles.
<HUAWEI> display air-scan-profile all
------------------------------------------------------------
Profile name Reference
------------------------------------------------------------
default 2
huawei 1
------------------------------------------------------------
Total: 2
Item |
Description |
---|---|
Profile name |
Name of an air scan profile. |
Reference |
Number of times that the air scan profile is referenced. |
# Display information about the air scan profile huawei.
<HUAWEI> display air-scan-profile name huawei ------------------------------------------------------------ Scan switch : enable Scan period(ms) : 80 Scan interval(ms) : 3000 Scan channel-set : dca-channel Scan enhancement : enable ------------------------------------------------------------
Item |
Description |
---|---|
Scan switch |
Whether air scanning is enabled. To configure the parameter, run the scan-disable command. |
Scan period(ms) |
Air scan period. To set the air scan period, run the scan-period command. |
Scan interval(ms) |
Air scan interval. To set the air scan interval, run the scan-interval command. |
Scan channel-set |
Air scan channel set. To set the air scan channel set, run the scan-channel-set command. |
Scan enhancement |
Whether the scanning enhancement function is enabled. To configure the scanning enhancement function, run the scan-enhancement command. |