< Home

display alarm active

Function

The display alarm active command displays active alarms on the device.

Format

display alarm active

Parameters

None

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

You can run the display alarm active command to view active alarms on the device to locate faults.

Example

# Display active alarms on the device.

<HUAWEI> display alarm active
A/B/C/D/E/F/G/H/I/J                                                                                                                 
A=Sequence, B=RootKindFlag(Independent|RootCause|nonRootCause)                                                                      
C=Generating time, D=Clearing time                                                                                                  
E=ID, F=Name, G=Level, H=State                                                                                                      
I=Description information for locating(Para info, Reason info)                                                                      
J=RootCause alarm sequence(Only for nonRootCause alarm)                                                                             
                                                                            
  92/Independent/2019-08-09 10:44:58/-/0x502001/linkDown/Critical/Start/OID 1.3.6.1.6.3.1.1.5.3 Interface 58 turned into DOWN state.
(AdminStatus=1,OperStatus=2,InterfaceName=40GE0/0/5)
Table 1 Description of the display alarm active command output

Item

Description

A/B/C/D/E/F/G/H/I/J

Alarm display format

A=Sequence

Sequence number

B=RootKindFlag(Independent|RootCause|nonRootCause)

Flag indicating a root-cause alarm or a non-root-cause alarm:

  • Independent: indicates an alarm for which alarm correlation analysis is not performed.
  • RootCause: indicates a root-cause alarm.
  • nonRootCause: indicates a non-root-cause alarm.

C=Generating time

Time when an alarm is generated

D=Clearing time

Time when an alarm is cleared

E=ID

Alarm ID

F=Name

Alarm name

G=Level

Alarm severity level

You can run the alarm-name severity command to set this parameter.

H=State

Alarm status:

  • Start
  • End

I=Description information for locating(Para info, Reason info)

Alarm description including alarm parameters and causes for triggering alarms

J=RootCause alarm sequence(Only for nonRootCause alarm)

Sequence number of the root-cause alarm (for non-root-cause alarms only)