< Home

display authentication associate

Function

The display authentication associate command displays the global configurations of associated users.

Format

display authentication associate

Parameters

None

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

Usage Scenario

To check the global configurations of associated users, run the display authentication associate command. The command output contains the suppression status of alarms that an authentication access device generates due to excess associated users and the configured alarm suppression period.

Precautions

This command is supported only on authentication access devices.

Example

# Display the global configurations of associated users.

<HUAWEI> display authentication associate
 authentication associate alarm-restrain: Enable
 authentication associate alarm-restrain period: 300
Table 1 Description of the display authentication associate command output

Item

Description

authentication associate alarm-restrain

Suppression status of alarms that an authentication access device generates due to excess associated users:
  • Enable
  • Disable

To configure a suppression status, run the authentication associate alarm-restrain enable command.

authentication associate alarm-restrain period

Suppression period for alarms that an authentication access device generates due to excess associated users.

To configure a suppression period, run the authentication associate alarm-restrain period command.