The display authentication associate alarm-restrain-table command displays suppression table information of alarms that are generated due to excess associated users.
display authentication associate alarm-restrain-table { all | interface interface-type interface-number }
Parameter |
Description |
Value |
---|---|---|
all |
Displays alarm suppression table information on all interfaces. |
- |
interface interface-type interface-number |
Displays alarm suppression table information on a specified interface.
|
- |
Usage Scenario
After an authentication access device is enabled to suppress alarms that are generated due to excess associated users using the authentication associate alarm-restrain enable command, run the display authentication associate alarm-restrain-table command to check the alarm suppression table information.
Precautions
This command is supported only on authentication access devices.
# Display alarm suppression table information on all interfaces.
<HUAWEI> display authentication associate alarm-restrain-table all
-------------------------------------------------------------------------------
Interface alarm time
-------------------------------------------------------------------------------
GigabitEthernet0/0/1 --
-------------------------------------------------------------------------------
Total 1
Item |
Description |
---|---|
Interface |
Interface that functions as an access point. |
alarm time |
Date and time when alarms were generated. |
Total: m |
Total number of suppressed entries m. |