< Home

display authentication associate alarm-restrain-table

Function

The display authentication associate alarm-restrain-table command displays suppression table information of alarms that are generated due to excess associated users.

Format

display authentication associate alarm-restrain-table { all | interface interface-type interface-number }

Parameters

Parameter

Description

Value

all

Displays alarm suppression table information on all interfaces.

-

interface interface-type interface-number

Displays alarm suppression table information on a specified interface.
  • interface-type specifies the type of the interface.
  • interface-number specifies the number of the interface.

-

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

Usage Scenario

After an authentication access device is enabled to suppress alarms that are generated due to excess associated users using the authentication associate alarm-restrain enable command, run the display authentication associate alarm-restrain-table command to check the alarm suppression table information.

Precautions

This command is supported only on authentication access devices.

Example

# Display alarm suppression table information on all interfaces.

<HUAWEI> display authentication associate alarm-restrain-table all
-------------------------------------------------------------------------------
Interface                    alarm time
-------------------------------------------------------------------------------
GigabitEthernet0/0/1         --
-------------------------------------------------------------------------------
    Total 1
Table 1 Description of the display authentication associate alarm-restrain-table all command output

Item

Description

Interface

Interface that functions as an access point.

alarm time

Date and time when alarms were generated.

Total: m

Total number of suppressed entries m.