< Home

display netconf alarm active

Function

The display netconf alarm active command displays the active alarms reported by the switch to NMS.

Format

display netconf alarm active

Parameters

None

Views

All views

Default Level

3: Management level

Usage Guidelines

After the NETCONF function is enabled on a switch, you can run the display netconf alarm active command to view the active alarms reported by the switch.

Example

# Display the active alarms reported by the switch to NMS.

<HUAWEI> display netconf alarm active
A/B/C/D/E/F/G                                                                                                                       
A=Sequence, B=Alarm type, C=Generating time                                                                                         
D=Name, E=Level, F=OID, G=Description                                                                                               
                                                                                                                                    
  1/equipmentAlarm/2019-08-27T02:15:42Z/hwPowerInvalid/critical/1.3.6.1.4.1.2011.5.25.219.2.5.5/Power supply is unavailable for some reason. 
(Index=67207181, EntityPhysicalIndex=67207181, PhysicalName="POWER Card 0/PWR2", EntityTrapFaultID=136973)
  2/equipmentAlarm/2019-08-27T02:15:59Z/hwPowerInvalid/critical/1.3.6.1.4.1.2011.5.25.219.2.5.5/Power supply is unavailable for some reason. 
(Index=68255757, EntityPhysicalIndex=68255757, PhysicalName="POWER Card 1/PWR2", EntityTrapFaultID=136973)   
Table 1 Description of the display netconf alarm active command output

Item

Description

A/B/C/D/E/F/G

Alarm format.

A=Sequence

Alarm sequence number.

B=Alarm type

Alarm type.

C=Generating time

Time when an alarm was generated

D=Name

Alarm name.

E=Level

Alarm severity.

F=OID

Alarm OID.

G=Description

Alarm description.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >