display fault-management alarm information (upgrade-compatible command)

Function

The display fault-management alarm information command displays registration information about an alarm message.

Format

display fault-management alarm information [ alarm-name ]

Parameters

Parameter Description Value
alarm-name Specifies the name of an alarm message. The value is a case-sensitive string of 1 to 256 characters without spaces.

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

None

Example

# Check registration information about the alarm message named linkUp.

<HUAWEI> display fault-management alarm information linkUp
**********************************                                              
  AlarmName: linkUp                                                             
  AlarmType: Resume Alarm                                                       
  AlarmLevel: Cleared                                                           
  Suppress Period: NA                                                           
  CauseAlarmName: linkDown                                                      
  Match VB Name: ifIndex                                                        
**********************************
Table 1 Description of the display fault-management alarm information command output

Item

Description

AlarmName

Name of an alarm message

AlarmType

Type of an alarm

AlarmLevel

Level of an alarm

Suppress Period

Suppress period of an alarm

CauseAlarmName

Name of the corresponding root alarm

Match VB Name

Contents of the matching rule set for the alarm messages