< Home

display monitor input

Function

The display monitor input command displays the status of an input line connected to a monitoring interface.

Only the S5720I-SI (except S5720I-6X-PWH-SI-AC and S5720I-10X-PWH-SI-AC) supports this command.

Format

display monitor input { line-id | all } [ slot slot-id ]

Parameters

Parameter Description Value

line-id

Displays the status of the specified input line.

The value is an integer that ranges from 1 to 2.

all

Displays the status of all input lines.

-

slot slot-id

Specifies the stack ID if stacking is configured.

The value is determined based on the device configuration.

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

You can run the display monitor input command to check the status of an input line connected to a monitoring interface, including the name, the normal level, and the current status of the input line, and whether the monitoring function is enabled.

Example

Display the current status of all input lines.

<HUAWEI> display monitor input all
                                                                                 
--------------------------------------------------------------------------      
LineID  LineName                        Enable  NormalStatus  CurrentStatus     
--------------------------------------------------------------------------      
1       Input1                          enable  low-level     abnormal          
2       Input2                          enable  high-level    normal            
--------------------------------------------------------------------------      
Table 1 Description of the display monitor input command output

Item

Description

LineID

ID of the input line connected to a monitoring interface.

LineName

Name of the input line connected to a monitoring interface. To set the name, run the monitor input command.

Enable

Whether an input line connected to a monitoring interface is enabled.

To set the parameter, run the monitor input enable command.

NormalStatus

Normal level of an input line connected to a monitoring interface:
  • low-level: The normal level is low level.

  • high-level: The normal level is high level.

To set the normal level, run the monitor input command.

CurrentStatus

Current status of an input line connected to a monitoring interface:
  • normal: The input line is in normal state.

  • abnormal: The input line is abnormal state.