< Home

display monitor output

Function

The display monitor output command displays the status of an output line connected to a monitoring interface.

Only the S5735-S-I supports this command.

Format

display monitor output { line-id | all }

Parameters

Parameter Description Value

line-id

Displays the status of a specified output line.

The value is 1.

all

Displays the status of all output lines.

-

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

After running the monitor output enable or undo monitor output enable command, you can run the display monitor output command to check the status of an output line connected to a monitoring interface, including line ID, the initial status of the monitoring function on the output line, and the current status of the monitoring function on the output line. If the initial status of the monitoring function on the output line is the same as the current status, the maintenance compartment door is closed. If they are inconsistent, the maintenance compartment door is opened.

Example

# Display the status of all output lines.

<HUAWEI> display monitor output all
-----------------------------------                                                                                                    
LineID  Config  Current Keeptime(s)                                                                                                    
-----------------------------------                                                                                                    
1       enable  enable  3                                                                                                           
-----------------------------------   
Table 1 Description of the display monitor output command output

Item

Description

LineID

ID of the output line connected to a monitoring interface.

Config

Initial status of the monitoring function on the output line.

  • enable: The monitor output enable command is run.
  • disable: The undo monitor output enable command is run.

Current

Current status of the monitoring function on the output line.

If the value of this field is the same as that of Config, the maintenance compartment door is closed. If they are inconsistent, the maintenance compartment door is opened.

Keeptime(s)

Hold time of the signals indicating the maintenance compartment door is open or closed when the monitoring function on the output line connecting to a monitoring interface is enabled. The unit is second.