The display monitor output command displays the status of an output line connected to a monitoring interface.
Only the S5735-S-I supports this command.
Parameter | Description | Value |
---|---|---|
line-id |
Displays the status of a specified output line. |
The value is 1. |
all |
Displays the status of all output lines. |
- |
After running the monitor output enable or undo monitor output enable command, you can run the display monitor output command to check the status of an output line connected to a monitoring interface, including line ID, the initial status of the monitoring function on the output line, and the current status of the monitoring function on the output line. If the initial status of the monitoring function on the output line is the same as the current status, the maintenance compartment door is closed. If they are inconsistent, the maintenance compartment door is opened.
# Display the status of all output lines.
<HUAWEI> display monitor output all
-----------------------------------
LineID Config Current Keeptime(s)
-----------------------------------
1 enable enable 3
-----------------------------------
Item |
Description |
---|---|
LineID |
ID of the output line connected to a monitoring interface. |
Config |
Initial status of the monitoring function on the output line.
|
Current |
Current status of the monitoring function on the output line. If the value of this field is the same as that of Config, the maintenance compartment door is closed. If they are inconsistent, the maintenance compartment door is opened. |
Keeptime(s) |
Hold time of the signals indicating the maintenance compartment door is open or closed when the monitoring function on the output line connecting to a monitoring interface is enabled. The unit is second. |