< Home

display uni-mng indirect configuration

Function

The display uni-mng indirect configuration command displays the indirect connection configuration on ASs.

This command can only be executed on an AS.

Format

display uni-mng indirect configuration

Parameters

None

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

You can run the display uni-mng indirect configuration command on an AS to check the indirect connection configuration on the AS.

Example

# Display the SVF indirect connection configuration on an AS.

<HUAWEI> display uni-mng indirect configuration
Uni-mng configuration information:                                                                                                  
 Current uni-mng status      : disable                                                                                              
 Next uni-mng status         : enable                                                                                               
 Current management VLAN     : --                                                                                                   
 Next management VLAN        : 100                                                                                                  
 Current fabric-port members :                                                                                                      
 Next fabric-port members    :                                                                                                      
  GigabitEthernet0/0/9           
Table 1 Description of the display uni-mng indirect configuration command output

Item

Description

Current uni-mng status Current manually configured client mode.
Next uni-mng status Next startup manually configured client mode.

To configure the client mode and management VLAN, run the uni-mng indirect mng-vlan command.

Current management VLAN Current management VLAN.

To configure the client mode and management VLAN, run the uni-mng indirect mng-vlan command.

Next management VLAN Next startup management VLAN.
Current fabric-port members Current member port configuration in a fabric port.

To configure member ports for a fabric port, run the uni-mng indirect fabric-port command.

Next fabric-port members Next startup member port configuration in a fabric port.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.