The flow-probe metadata-collect server command configures the IP address and port number of the CIS server.
The undo flow-probe metadata-collect server command deletes the configured IP address and restores the configured port number to the default value.
By default, the IP address of the CIS server is not specified and the default port number is 8514.
flow-probe metadata-collect server ip ip-address [ port port-number ]
undo flow-probe metadata-collect server
Parameter | Description | Value |
---|---|---|
ip ip-address | Specifies the IP address of the CIS server. |
The value is an IPv4 address in dotted decimal notation. |
port port-number | Specifies the port number of the CIS server. |
The value is an integer ranging from 1 to 65535. |
Usage Scenario
The default port number of the peer CIS server connected to the flow probe metadata collector is subject to the metadata collection and transmission mode. Current switch only support UDP protocol for the metadata transmission, the default port number is 8514.
Prerequisites
Before running this command, you must run the defence engine enable command to enable the IAE.