The flow-probe metadata-collect source command configures the source IP address and VPN instance name of the packet sent from the ECA flow probe metadata to the CIS server.
The undo flow-probe metadata-collect source command restores the configured source IP address and VPN instance name to the default values.
By default, the source IP address of the packet sent from the ECA flow probe metadata to the CIS is empty.
flow-probe metadata-collect source { ip ip-address port port-number | vpn-instance vpn-instance-name } *
undo flow-probe metadata-collect source
Parameter | Description | Value |
---|---|---|
ip ip-address | Specifies the source IP address of the packet sent from the ECA flow probe metadata to the CIS server. |
The value is in dotted decimal notation. |
port port-number | Specifies the source port number of the packet sent from the ECA flow probe metadata to the CIS server. |
The value is an integer that ranges from 1 to 65535. |
vpn-instance vpn-instance-name | Specifies the VPN instance name of the packet sent from the ECA flow probe metadata to the CIS server. |
The value must be the name of an existing VPN instance. |
Usage Scenario
When configuring the source IP address of the packet sent from the ECA flow probe metadata to the CIS server, ensure that the IP address is the device interface IP address and that this interface IP address is reachable to the CIS server.
Prerequisites
Before running this command, you must run the defence engine enable command to enable the IAE.