< Home

high-temperature threshold

Function

The high-temperature threshold command sets an upper device, ambient, CPU, or NP chip temperature alarm threshold for APs.

The undo high-temperature threshold command restores the default upper device, ambient, CPU, or NP chip temperature alarm threshold of APs.

Table 1 Default upper temperature alarm threshold for APs

AP Model

Default Value (°C)

R230D/R240D

40

AD9431DN-24X/AD9430DN-24

71

AP4050DN-HD

79

AP8050DN/AP8050DN-S/AP8150DN/AP9330DN/AP7030DE

83

AP9131DN/AP9132DN

84

AP8030DN/AP6050DN/AP6150DN/AP5050DN-S/WA375DD-CE

86

AP4030TN/AP5030DN/AP5130DN/AP5030DN-S

87

AP8130DN/AP7050DE/AP7052DN/AP7152DN/AP6052DN/AP4051TN

88

AP7050DN-E

89

AP4050DE-M/AP4050DE-M-S/AirEngine 5760-10

90

AP8082DN/AP8182DN/AP8050TN-HD/AD9430DN-12

91

AP4050DN-E

92

AP7052DE/R251D/R251D-E

95

AP4050DN/AP1050DN-S/R450D

96

R250D/R250D-E

102

This command is unavailable for the AP3050DE, AP4050DE-B-S, AP2051DN-L-S, AP5510-W-GP, AP4030DN-E, AP2030DN, AP2030DN-S, AP2050DN, AP2051DN, AP2050DN-S, AP2051DN-S, AP2050DN-E, AP2051DN-E, AP430-E, AP3010DN-V2, AP3030DN, AP4030DN, AP4051DN, AP4151DN, AP4050DN-S, AP4051DN-S, AP4130DN, AirEngine 8760-X1-PRO, AirEngine 6760-X1, AirEngine 6760-X1E, AirEngine 5760-51, AirEngine 5760-22W, AirEngine 8760R-X1, AirEngine 8760R-X1E, AirEngine 6760R-51, AirEngine 6760R-51E, and AirEngine 5760-22WD.

Format

high-temperature [ ap-environment | cpu | np ] threshold threshold

undo high-temperature [ ap-environment | cpu | np ] threshold

Parameters

Parameter

Description

Value

ap-environment

Indicates the ambient temperature.

-

cpu

Indicates the CPU temperature.

-

np

Indicates the NP chip temperature.

-

threshold

Specifies the upper temperature alarm threshold.

The value is an integer that ranges from 20 to 110, in °C.

Views

AP system profile view

Default Level

2: Configuration level

Usage Guidelines

You can run this command to set the upper temperature alarm threshold for an AP. When an AP's temperature exceeds the upper threshold, the AP generates an alarm and a log, and notifies the AC of the high temperature alarm.

If ap-environment | cpu | np is not specified, this command sets an upper temperature alarm threshold for APs.

Example

# Set the upper temperature alarm threshold for APs to 65°C.

<HUAWEI> system-view
[HUAWEI] wlan 
[HUAWEI-wlan-view] ap-system-profile name ap-system1
[HUAWEI-wlan-ap-system-prof-ap-system1] high-temperature threshold 65
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >