The interference station threshold command configures the alarm threshold for STA interference.
The undo interference station threshold command restores the default alarm threshold for STA interference.
By default, the alarm threshold for STA interference is 32.
Parameter |
Description |
Value |
---|---|---|
threshold-value |
Specifies the alarm threshold. |
The value is an integer that ranges from 1 to 256. |
If there are many STAs that are managed by other APs around an AP, services of the STAs managed by the local AP may be affected.
After the interference detect-enable command is executed to enable interference detection, an AP can detect STAs that are managed by other APs. When the AP detects that the number of such STAs exceeds the alarm threshold configured using the interference station threshold command, the AP sends an alarm to the AC.