The interval command sets the interval at which NQA test packets are sent.
The undo interval command restores the default setting.
By default, the intervals for sending test packets in various tests are as follows:
The interval is 4 seconds for other test instances.
Parameter | Description | Value |
---|---|---|
milliseconds interval | Sets the interval at which packets are sent, in milliseconds. NOTE:
If the configured interval is a multiple of 1000 milliseconds, the system will automatically convert milliseconds into seconds. |
The value is an integer that ranges from 20 to 60000. |
seconds interval | Sets the interval at which packets are sent, in seconds. | The value is an integer that ranges from 1 to 60, in seconds. |
Usage Scenario
In an NQA test instance, multiple probes are sent. Statistics obtained from multiple probe tests show the network quality. Probe packets (or probes) are sent at a specified interval.
Prerequisites
The type of a test instance has been specified using the test-type command. The interval command is valid only for the ICMP, ICMP Jitter, Path Jitter, SNMP, LSP Jitter, LSP Ping, PWE3 Ping, TCP, UDP, or UDP Jitter test instances.
Configuration Impact
Precautions
The interval for sending packets of a running test instance cannot be changed.