< Home

iplpm global loss-measure alarm enable

Function

The iplpm global loss-measure alarm enable command enables the alarm and clear alarm of the packet loss ratio for device-level packet loss measurement.

The undo iplpm global loss-measure alarm enable command restores the default setting.

By default, the alarm and clear alarm of the packet loss ratio are disabled.

Format

iplpm global loss-measure alarm enable

undo iplpm global loss-measure alarm enable

Parameters

None

Views

System view

Default Level

2: Configuration level

Usage Guidelines

After this command is used, the alarm threshold and clear alarm threshold of the packet loss ratio are 5% and 1%.
  • If the packet loss ratio in five consecutive measurement intervals exceeds the alarm threshold, the device reports the hwIpfpmLossRatioExceed alarm to the NMS to notify the link fault in real time.
  • If the packet loss ratio in five consecutive measurement intervals falls below or is equivalent to the clear alarm threshold, the device reports the hwIpfpmLossRatioRecovery alarm to the NMS to notify link recovery in real time.

Example

# Enable the alarm and clear alarm of the packet loss ratio for device-level packet loss measurement.

<HUAWEI> system-view
[HUAWEI] iplpm global loss-measure alarm enable
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >